タイトル: | Application of susceptibility weighted imaging (SWI) for evaluation of draining veins of arteriovenous malformation: utility of magnitude images. |
著者: | Miyasaka, Toshiteru Taoka, Toshiaki Nakagawa, Hiroyuki Wada, Takeshi Takayama, Katsutoshi Myochin, Kaoru Sakamoto, Masahiko Ochi, Tomoko Akashi, Toshiaki Kichikawa, Kimihiko |
キーワード: | Susceptibility weighted image Magnitude image Arteriovenous malformation Magnetic resonance imaging |
発行日: | 2012年11月1日 |
出版者: | Springer-Verlag |
引用: | Neuroradiology Vol.54 No.11 p.1221-1227 |
抄録: | INTRODUCTION: The current study evaluated the signal characteristics of susceptibility weighted imaging (SWI) of arteriovenous malformation (AVM), especially for draining veins. For this purpose, we identified the draining veins of the AVM on angiography and evaluated the signal on magnitude image for SWI (SWI-mag) and minimum intensity projection image (SWI-minIP).
METHODS: Subjects were 14 cases with angiographically proven AVM. SWI-mag, SWI-minIP, and time-of-flight (TOF) magnetic resonance angiography were acquired. For the draining veins of the AVM identified on angiography, we analyzed signal intensity on the images listed above, and classified it into hyperintensity (hyper), mixed intensity (mixed), hypointensity (hypo), and no visualization.
RESULTS: On the analysis of 27 angiographically proven draining veins, 19 draining veins were classified as hyper, 3 as mixed, 0 as hypo, and 6 as no visualization on SWI-mag. On TOF images, 21 draining veins were classified as hyper, 2 as mixed, 0 as hypo, and 4 as no visualization, while 6 draining veins did not show hyperintensity on TOF, and SWI-mag visualized 3 of these 6 veins as hyper.
CONCLUSION: SWI-mag depicted most draining veins of AVM as hyperintensity. We speculate that this is mainly due to the higher concentration of oxygenated hemoglobin (oxy-Hb) and inflow effect of the draining vein. SWI-mag seems to be useful in the analysis and follow-up for AVM as the signal on the image may reflect physiological status. |
内容記述: | 博士(医学)・乙第1316号・平成25年7月22日 |
URI: | http://hdl.handle.net/10564/2638 |
ISSN: | 00283940 |