|
GINMU >
01 奈良県立医科大学 >
012 大学院 >
0122 学位請求論文 >
01221 博士論文(医学) >
2015年度 >
このアイテムの引用には次の識別子を使用してください:
http://hdl.handle.net/10564/3083
|
タイトル: | Impact of A Transparent Hood on The Performance and Therapeutic Result of Endoscopic Injection Sclerotherapy. |
その他のタイトル: | 内視鏡的硬化療法の手技と治療成績における透明フードの有用性 |
著者: | Uejima, Masakazu Matsumura, Masahiko Umemoto, Norie Yoshida, Motoyuki Sawai, Masayoshi Namisaki, Tadashi Kitade, Mitsuteru Kawaratani, Hideto Takaya, Hiroaki Aihara, Yosuke Mitoro, Akira Yoshiji, Hitoshi Yamao, Junichi Fukui, Hiroshi |
キーワード: | Oblique transparent hood Endoscopic injection sclerotherapy (EIS) Intravariceal injection Variceal recurrence |
発行日: | 2014年12月31日 |
出版者: | 奈良医学会 奈良県立医科大学 |
引用: | Journal of Nara Medical Association Vol.65 No.4,5,6 p.51-61 |
抄録: | Objective: Although the effectiveness of a transparent hood has been reported in various endoscopic procedures, there are only a few reports regarding the benefit of a transparent hood in endoscopic injection sclerotherapy(EIS). In the current study, we conducted a retrospective evaluation of the efficacy and long-term benefit of an oblique transparent hood on EIS. Methods: The transparent hood, manufactured by Olympus (MAJ295 or MAJ296), consisted of a reusable wide oblique distal attachment with rim. This hood was attached when the varix was fine (F0 or F1). In this retrospective study, a total of 201 patients were recruited, and 99 patients (designated as the "Hood Group") received this hood while 102 patients (designated as the "Conventional Group") did not. We compared the rate of intravariceal injection, enhanced supply vessels, variceal eradication, and recurrence between these two groups. Results: This transparent hood provided a better visual field, and there was no serious complication in any of the patients. Intravariceal injection rates in the Hood Group and Conventional Group were 73.9% (190/257) and 57.7% (146/253) respectively (p<0.01). The rates of enhanced supply vessels in the Hood Group and Conventional Group were 89.8% (89/99) and 72.5% (74/102) respectively (p<0.01). The rates of variceal eradication did not differ significantly. We also assessed the cumulative non-recurrence probability for up to 3000 days between the two groups. The Hood Group was statistically superior to the Conventional Group (p<0.01) Conclusion: The application of an oblique transparent hood method is safe and effective for intravariceal EIS. This hood contributes especially to reduction of the long-term recurrence probability. |
内容記述: | 博士(医学)・乙第1365号・平成27年11月27日 |
URI: | http://hdl.handle.net/10564/3083 |
ISSN: | 13450069 |
学位授与番号: | 24601B1365 |
学位授与年月日: | 2015-11-27 |
学位名: | 博士(医学) |
学位授与機関: | 奈良県立医科大学 |
出現コレクション: | 2015年度 Vol.65 No.4,5,6
|
このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。
|