DSpace DSpace Softwareについて English
 

GINMU >
01 奈良県立医科大学 >
012 大学院 >
0122 学位請求論文 >
01221 博士論文(医学) >
2019年度 >

このアイテムの引用には次の識別子を使用してください: http://hdl.handle.net/10564/3699

タイトル: Use of a Glass Membrane Pumping Emulsification Device Improves Systemic and Tumor Pharmacokinetics in Rabbit VX2 Liver Tumor in Transarterial Chemoembolization.
その他のタイトル: 膜乳化デバイスによるエマルションを用いたウサギVX2肝腫瘍モデノレへの肝動脈化学塞栓術における抗腫瘍効果、薬物動態の検討
著者: Masada, Tetsuya
Tanaka, Toshihiro
Nishiofuku, Hideyuki
Fukuoka, Yasushi
Taiji, Ryosuke
Sato, Takeshi
Tatsumoto, Shota
Minamiguchi, Kiyoyuki
Marugami, Nagaaki
Kichikawa, Kimihiko
発行日: 2020年2月
出版者: Elsevier
引用: Journal of vascular and interventional radiology Vol.31 No.2 p.347-351 (2020 Feb)
抄録: Purpose: To evaluate the phamacokinetics of epirubicin in conventional transarterial chemoembolization using a developed pumping emulsification device with a microporous glass membrane in VX2 rabbits. Materials and methods: Epirubicin solution (10 mg/mL) was mixed with ethiodized oil (1:2 ratio) using the device or 3-way stopcock. Forty-eight rabbits with VX2 liver tumor implanted 2 weeks prior to transarterial chemoembolization were divided into 2 groups: a device group (n = 24) and a 3-way-stopcock group (n = 24). Next, 0.5 mL of emulsion was injected into the hepatic artery, followed by embolization using 100-300-μm microspheres. The serum epirubicin concentrations (immediately after, 5 minutes after, and 10 minutes after) and the tumor epirubicin concentrations (20 minutes after and 48 hours after) were measured after transarterial chemoembolization. Histopathologic evaluation was performed with a fluorescence microscope. Results: The area under the curve and maximum concentrations of epirubicin in plasma were 0.45 ± 0.18 μg min/mL and 0.13 ± 0.06 μg/mL, respectively, in the device group and 0.71 ± 0.45 μg min/mL and 0.22 ± 0.17 μg/mL, respectively, in the 3-way-stopcock group (P = .013 and P = .021, respectively). The mean epirubicin concentrations in VX2 tumors at 48 hours in the device group and the 3-way-stopcock group were 13.7 ± 6.71 and 7.72 ± 3.26 μg/g tissue, respectively (P = .013). The tumor necrosis ratios at 48 hours were 62 ± 11% in the device group and 51 ± 13% in the 3-way-stopcock group (P = .039). Conclusions: Conventional transarterial chemoembolization using the pumping emulsification device significantly improved the pharmacokinetics of epirubicin compared to the current standard technique using a 3-way stopcock.
内容記述: 博士(医学)・乙第1443号・令和元年12月5日
Copyright © 2019 SIR. Published by Elsevier Inc. All rights reserved.
URI: http://hdl.handle.net/10564/3699
ISSN: 10510443
DOI: https://doi.org/10.1016/j.jvir.2019.06.015
学位授与番号: 24601B1443
学位授与年月日: 2019-12-05
学位名: 博士(医学)
学位授与機関: 奈良県立医科大学
出現コレクション:2019年度

このアイテムのファイル:

ファイル 記述 サイズフォーマット
01乙1443本文の要旨.pdf乙1443本文の要旨1.41 MBAdobe PDF見る/開く
02乙1443審査要旨.pdf乙1443審査要旨6.49 MBAdobe PDF見る/開く
03乙1443本文.pdf乙1443本文652.78 kBAdobe PDF見る/開く

このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。

 

Valid XHTML 1.0! Powered by DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - ご意見をお寄せください