DSpace DSpace Softwareについて English
 

GINMU >
01 奈良県立医科大学 >
011 医学部 >
0112 紀要 >
01121 Journal of Nara Medical Association >
Vol.50 No.3 >

このアイテムの引用には次の識別子を使用してください: http://hdl.handle.net/10564/512

タイトル: 透析膜生体適合性評価におけるHPLCによる血清ネオプテリン測定の有用性 : ビタミンE固相化改質セルロース膜における基礎的・臨床的評価
その他のタイトル: SERUM NEOPTERIN AS THE MARKER FOR BIOCOMPATIBILITY IN HEMODIALYSIS : EXPERIMENTAL AND CLINICAL EVALUATION OF VITAMIN E COATED CELLULOSE DIALYZER BY SERUM NEOPTERIN
著者: 中辻, 史好
米田, 龍生
影林, 頼明
大園, 誠一郎
平尾, 佳彦
吉田, 克法
キーワード: Neopterin
Hemodialysis
Vitamin-E coated dialyzer
Biocompatibility
発行日: 1999年6月30日
出版者: 奈良医学会
引用: Journal of Nara Medical Association Vol.50 No.3 p.174-182
抄録: Exposure of blood to hemodialysis membranes results in numerous phenom- ena or complications in hemodialysis (HD) patients, and these complications influence the quality of life (QOL) in HD patients. Vitamin E coated cellulose dialyzer (E-membrane) is developed to act as scavenger for reactive oxgen species which couse complications in HD patients. Neopterin (NEOP) is the metabolites derived from guanosine triphosphate. Recently it was shown that production and release of NEOP is induced in monocyte and macrophages by cytokines such as interferon gamma (IFN-γ). And it is surmised to be as a reactive marker of biocompatibility of dialysis membrane in hemodialyzed patients. In this study, we evaluated the usefulness of serum NEOP as a marker for biocompatibility of dialyzer by the use of E-membrane and control membrane in experimen- tal and clinical study. In experimental study in using dogs, exracorporal circulation with E-membrane and control membrane, the serial levels of serum NEOP in dogs using E- membrane were lower than those of control membrane about the ratio of serum NEOP. In clinical study, during extracorporal ultrafiltration methods (ECUM), the levels of serum NEOP in patients using E-membranes were lower than those in patients using control membranes. In long time evaluation of biocompatibility of there two membranes, the ratio of increasing of serum NEOP using control membranes was higher than that using E- membranes. By evaluation of serum NEOP for biocompatibility of membrane in dialysis, our observa- tion showed that serum NEOP is useful as a marker of biocompatibility in hemodialysis membrane.
URI: http://hdl.handle.net/10564/512
ISSN: 13450069
出現コレクション:Vol.50 No.3

このアイテムのファイル:

ファイル 記述 サイズフォーマット
174-182p.透析膜生体適合性評価におけるHPLCによる血清ネオプテリン測定の有用性.pdf922.21 kBAdobe PDF見る/開く

このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。

 

Valid XHTML 1.0! Powered by DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - ご意見をお寄せください