DSpace DSpace Softwareについて English
 

GINMU >
01 奈良県立医科大学 >
012 大学院 >
0122 学位請求論文 >
01221 博士論文(医学) >
2020年度 >

このアイテムの引用には次の識別子を使用してください: http://hdl.handle.net/10564/3828

タイトル: Motor evoked potential monitoring can evaluate ischemic tolerance to carotid artery occlusion during surgery.
その他のタイトル: 術中運動誘発電位モニタリングによる内頚動脈閉塞に対する虚血耐性評価
著者: Takamura, Yoshiaki
Motoyama, Yasushi
Takatani, Tsunenori
Takeshima, Yasuhiro
Matsuda, Ryosuke
Tamura, Kentaro
Yamada, Shuichi
Nishimura, Fumihiko
Nakagawa, Ichiro
Park, Young-Su
Nakase, Hiroyuki
キーワード: Balloon test occlusion
Carotid artery occlusion
Intraoperative neurophysiological monitoring
Ischemic tolerance
Motor evoked potential
発行日: 2020年7月31日
出版者: Springer Nature
引用: Journal of clinical monitoring and computing Vol.35 No.5 p.1055-1062 (2021 Oct)
抄録: Balloon test occlusion (BTO) is a useful examination for evaluating ischemic tolerance to internal carotid artery (ICA) occlusion. The aim of this study was to investigate the relationships between intraoperative motor evoked potential (MEP) monitoring and the results of preoperative BTO. Between 2013 and 2017, 32 patients undergoing surgery under general anesthesia with intraoperative MEP monitoring, in whom preoperative BTO was performed, were identified. A receiver operator characteristic (ROC) analysis was performed to determine the appropriate cutoff value of MEP amplitude for BTO-positive. Furthermore, the accuracy of MEP monitoring for BTO-positive was compared with electroencephalogram (EEG) and somatosensory evoked potential (SEP) monitoring. Four of 32 (12.5%) patients were BTO-positive. The cutoff value of MEP amplitude for BTO-positive was a > 80% reduction from the baseline level, which showed sensitivity of 100% and specificity of 100%. Thus, the sensitivity and specificity for BTO-positive were significantly higher for MEP than for EEG (100% and 72.0%, p = 0.02) in 28 patients, but they were not significantly different compared with SEP (33.3% and 100%, p = 0.48) in 21 patients. MEP monitoring might be one of the alternatives for evaluating ischemic tolerance to ICA occlusion during surgery. The cutoff value of MEP amplitude was a > 80% reduction.
内容記述: 博士(医学)・乙第1483号・令和2年12月24日
© Springer Nature B.V. 2020
This is a post-peer-review, pre-copyedit version of an article published in Journal of clinical monitoring and computing. The final authenticated version is available online at: http://dx.doi.org/10.1007/s10877-020-00573-0.
URI: http://hdl.handle.net/10564/3828
ISSN: 13871307
DOI: https://doi.org/10.1007/s10877-020-00573-0
学位授与番号: 24601B1483
学位授与年月日: 2020-12-24
学位名: 博士(医学)
学位授与機関: 奈良県立医科大学
出現コレクション:2020年度

このアイテムのファイル:

ファイル 記述 サイズフォーマット
01乙1483本文の要旨.pdf乙1483本文の要旨1.16 MBAdobe PDF見る/開く
02乙1483審査要旨.pdf乙1483審査要旨86.86 kBAdobe PDF見る/開く
03乙1483本文.pdf乙1483本文6.93 MBAdobe PDF見る/開く

このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。

 

Valid XHTML 1.0! Powered by DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - ご意見をお寄せください